Specific Applications 2D-LC Dual LC Inverse gradient for charged aerosol detection Multichannel / Multiplex Purification / Fractionation Tandem LC Method development Proteomics. Biocompatible Yes No. Brand Vanquish UltiMate 3000 EASY-nLC Transcend. System Compatibility Application-specific Analytical Nano, Capillary and Microflow.
Identify and correct common HPLC problems to restore column performance. Get help with peak problems (peak splitting, peak tailing, peak fronting, etc.), retention time, purge noise, and loss of resolution with example chromatograms.
Snap vials sealed with snap caps are easy to apply and remove without the need for crimping or de-capping tools. These chemically inert polyethylene caps are an economical choice for most routine HPLC applications but have low sealing property. Snap caps have a large open area allowing easy needle penetration across the entire vial opening.
1.5 mm 55° shore A ND 13 (13mm) 4mL screw vial kit, including vial, cap and septa, 100/pack Kit part number Vial Vial part number Septa Material Cap/Septa part number 220-91521-10 Clear - Low Volume - PTFE/Silicone, ultra-clean - 220-97331-23 Clear with write on spot 220-97331-17 PTFE/Silicone, ultra-clean 220-97331-20
Shimadzu has released Shim-pack MC PLONAS Series. Shim-pack MC PLONAS 2.7 μm columns reduce the back pressure yet maintain the performance of a sub 2 μm fully porous particle column. The pressure limit is 40 MPa. Shimadzu has released the High-speed Organic Acid Analysis Column Shim-pack Fast-OA.
Snap vials sealed with snap caps are easy to apply and remove without the need for crimping or de-capping tools. These chemically inert polyethylene caps are an economical choice for most routine HPLC applications but have low sealing property. Snap caps have a large open area allowing easy needle penetration across the entire vial opening.
An application/technical note (Pub no. 5980-1193) and detailed instructions (Aijiren ZORBAX Eclipse AAA Instructions for Use Pub no 5980(Aijiren ZORBAX Eclipse AAA Instructions for Use, Pub no. 5980-3088EN, June 2008) are available. The method has been in place for a number of years and is reliable.
2ml clear or amber autosampler vial,12mm Diameter,32mm Height,9-425 screw top.Our vials with caps are widely used in standard HPLC and GC applications.The vials can be used on all common autosamplers due to their technical geometry, preferentially they are found on Aijiren, HTA, Shimadzu, Thermo, Varian, Waters, etc.
Note: For vials, caps/septa, and small glass inserts, obtain number 1 or 2 (set) in the table. Item Recommended Products Column Rinse solution vial Rinse solution vial cap Rinse solution vial septum Standard mixture of n-Alkanes Vial 4 mL (221-34267-92) Vial cap 4 mL (221-34268-92) Vial septum 4 mL (221-34266-92)
Since 1875, Shimadzu is pursuing leading-edge science and technologies in analytical and measuring instruments including chromatographs and mass spectrometers, medical devices, aeronautics, and industrial equipment.
Ensure the ultimate in resolution and sensitivity for cannabis analysis by using the Shimadzu columns. Shimadzu provides the ultimate separation for all of your pesticide analysis needs. Item Number. Item Name. Description. Store Link. 221-75940-30. Rxi-5ms. GC Column, 30m X 0.25mm X 0.25um.
The specification of 10ml Crimp Top GC Vial is 22.5*46mm. 10ml Crimp Top GC Vial for SHIMADZU. Aijiren’s 8mm HPLC Vial and PP Cap are the best match for Shimadzu autosamplers. The opening is 8mm and the long thread design ensures the tightness of the cap when tightening.
1.5mL Vials 4mL Vials Headspace Vials (10 & 20mL) EPA Screw Vials LabTotal Vial MS Certified Kit (13mm) 220-97331-21: Black PP, Center hole ... Shimadzu LabTotal ...
High-performance liquid chromatography with PDA was used for routine quantification of allicin. The system consisted of a Shimadzu HPLC-PDA (Shimadzu, Kyoto, Japan) with an Aijiren Varian C18 column (250 mm x 4.6 mm, 5 μm) at room temperature.
Therefore, we aimed to develop and validate a simple, rapid, cost-effective high performance liquid chromatography (HPLC) method for the quantification of cefiderocol in serum. Samples were treated for protein precipitation followed by chromatographic separation on a reverse phase column (HPLC C-18) with gradient elution of the mobile phase.