2021 08 17
HPLC Vials and Laboratory Equipment Manufacturer | Althea
We are a well-known Manufacturer, Importer and Exporter of HPLC Vials, Solvent Filter, Manual Crimper, Syringe Filters, Silicone Septa, Amber Glass Bottle, Filtration Kit, KBR Die Set, Polypropylene Vial, HPLC Consumables, etc.
Get Price >> -
2021 08 17
Whatman syringe filter and filter vial collection - Fisher Sci
volume with decreased hand pressure. HPLC/UHPLC sample preparation by eliminating multiple consumables. These devices act both as filters and autosampler vials. Puradisc syringe filters provide quick, efficient filtration ... membrane filter, and septum/cap
Get Price >> -
2021 08 17
Aijiren HPLC | SOP For Aijiren With Empower Software
7/8/2021 · Acceptance criteria: All vial septum shall be punctured. Injection Accuracy. Fill a standard 2-mL vial with 5mL of degassed HPLC-grade water and close the vial with a septum and cap. Note: Use forceps or wear lint-free gloves to handle the vial in this; Weigh the vial (using forceps or gloved hand to move the vial). Record the weight (Wl).
Get Price >> -
2021 08 17
SOP for Calibration of Shimadzu HPLC (Prominence – i LC
12/7/2020 · Take HPLC grade water in one of the vial and stoppered with septa. Weigh the vial with water (W1). Place the vial in the sample compartment. Set the system to inject 10 injections with 10µl- injections volume. Take the vial and reweigh it (W2). Difference in weight gives the weight of water drawn by the auto injector. (W1-W2).
Get Price >> -
2021 08 17
Limited-Volume 2.0 mL, 9 mm Screw-Thread Polypropylene Vials
Limited-volume design fits all 2.0 mL, 12 x 32 mm, vial-based autosamplers. Compatible with all 9 mm screw-thread caps. PTFE-free—ideal for PFAS analysis (e.g., EPA 537) and other PFAS-sensitive methods. Note: Polypropylene vials and caps prevent sample contamination from PTFE-coated septa. However, since polypropylene caps do not reseal
Get Price >> -
2021 08 17
Autosampler Vials, Caps and Closures | Fisher Scientific
Get Price >> -
2021 08 17
Routine Sample Handling - Thermo Fisher Scientific
Standard HPLC Septa 60 1.0 100 60180A-SC9STB1 9mm Blue Screw Cap, Silicone/PTFE Bonded Septa Special HPLC Septa 45 1.0 100 60180A-SC9STBS1 9mm Blue Screw Cap, Silicone/PTFE Bonded Septa, Slitted Special HPLC Septa 45 1.0 100 Wide Opening 2ml Glass Crimp Vials 12 x 32mm Crimp Vials 11mm Category Cat. No. Description Total Capacity Usable Volume
Get Price >> -
2021 08 17
(PDF) HPLC Autosamplers: Perspectives, Principles, and
This installment is the second of a series of four white papers on high-performance liquid chromatography (HPLC) modules focusing on septa; pa rtic les from t he ... per that captures the vial ...
Get Price >> -
2021 08 17
Tips and Tricks for HPLC and UHPLC - Thermo Fisher Scientific
needle. Fill 2/3 of the volume. • If you use inserts make sure there are no airbubbles in them. • Autosamplers with PEEK™ (Victrex Plc.) needle must have caps with slit septa. • Never shake the vial. If you do there is going to be sample on the underside of the septum which gives carry over.
Get Price >> -
2021 08 17
Interlock Vials - Restek
Interlock limited volume vials offer the performance and convenience of a one-piece microvial for a fraction of the cost. A 300 µL insert is fused into a 12 x 32 mm clear or amber glass vial. This one-piece design reduces the potential for contamination.
Get Price >> -
2021 08 17
Thermo Scientific™ Dionex™ AS-AP Autosampler Vial Kit
Description Septa included are blue. Specification VolumeMetric 10 mL Unit 0 Qualifier cl_2643551 Productsapid 55058 Language en Valueposition 0 Thermo Scientific™ Dionex™ AS-AP Autosampler Vial Kit, polystyrene, 10mL, with caps and septa
Get Price >> -
2021 08 17
HPLC Tips & Tricks - Thermo Fisher Scientific
• Do not overfill the vial – the septum is used to clean the needle. Fill 2/3 of the volume • If you use inserts make sure there are no airbubbles in them • Autosamplers with PEEK needle must have caps with slit septa • Never shake the vial. If you do there is going to be sample on the underside of the septum
Get Price >> -
2021 08 17
Standard|Filter Vial - Thomson | Solutions At Work
Thomson Standard Filter Vials can be used for samples containing less than 10% solid particulates. The filter vial consists of two parts: a filter vial shell and a plunger which includes a single layer filter on one end and a vial cap on the other end. Applications for Standard Filter Vials include filtration of catalysts from organic and
Get Price >> -
2021 08 17
High Performance Liquid Chromatography Vial Selection Guide
Septa Quality The 1.5 and 4mL vials use a PTFE/silicone septum and its cleanliness is suitable for everyday applications as well as the most discriminating LCMS analyses. The septum is press-fit inside the cap without any bonding agents, which could potentially contaminate samples. It also prevents the needle from pushing the septum into the vial.
Get Price >> -
2021 08 17
Autosampler Vials | Fisher Scientific
Autosampler Vials Thermo Scientific™ 20 mm Headspace Vials, Septum, and Caps Headspace vials are available in clear or amber glass with a round or flat base, a crimp seal with a beveled or square edge finish, or with a screw-thread finish.
Get Price >>